PRODUCTS > INTELLIGENT I/O MODULES |
|
Digital input modules |
|
DI-1008 FT
Fully programmable LON module with 8 isolated polarity insensitive digital inputs. Suitable for implementation in building automation and industrial applications. Free topology communication (FTT-10). Ultra wide power supply range from 9 to 70VDC (18 to 48VAC). |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
LDE 4
LON module with 4 digital inputs. Suitable to record the status of potential free switches, e.g. electronic limit switches at vent valves or auxiliary contacts at power contactors.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
LDE 4 IP65 housing
LON module with 4 digital inputs. Suitable to record the status of potential free switches, e.g. electronic limit switches at vent valves or auxiliary contacts at power contactors. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
LDE 230
LON module with 4 digital input. Suitable to record the status of 230 VAC switches, e.g. switches or tact switches for light control.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
|
LDE 10
LON module with 10 digital inputs. Suitable to record the status of potential free switches, e.g. electrical limit switches at vent valves or auxiliary contacts at power contactors.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
LDE 10 IP housing
LON module with 10 digital inputs. Suitable to record the status of potential free switches, e.g. electrical limit switches at vent valves or auxiliary contacts at power contactors.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
^ top page |
|
Digital output modules |
|
DO-1008 FT
Fully programmable LON module with 8 relay outputs with normally opened contacts. Suitable for implementation in building automation and industrial applications. Free topology communication (FTT-10). Ultra wide power supply range from 9 to 70VDC (18 to 48VAC). |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
|
|
|
|
LT04
LON module with 4 digital outputs. Suitable to switch electrical components such as relays, contactors, valves etc. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
|
LRAS 4/21
LON module with 4 relay outputs. Suitable to switch electrical components such as motors, contactors, lamps, blinds etc. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
LRAS 4/21 IP65 housing
LON module with 4 relay outputs. Suitable to switch electrical components such as motors, contactors, lamps, blinds etc. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
^ top page |
|
Analog input modules |
|
NC1102
LON module with 6 isolated analog current (0-20mA) inputs. Wide power supply range from 9 to 70VDC (18 to 48VAC).
|
|
|
|
|
|
|
|
|
|
|
|
NC1103
LON module with 6 isolated analog voltage (0-10V) inputs. Wide power supply range from 9 to 70VDC (18 to 48VAC).
|
|
|
|
|
|
|
|
|
|
|
|
NC1104
LON module with 4 isolated analog inputs for Pt100 temperature sensor. Wide power supply range from 9 to 70VDC (18 to 48VAC).
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NC1105
LON module with 4 isolated analog inputs for thermocouple. Wide power supply range from 9 to 70VDC (18 to 48VAC).
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LAE 8
LON module with 8 inputs, each configurable as temperature or voltage input, to record temperatures or voltages e. g. of passive or active temperature sensors, electrical ventilation or mixing valves, valve positions etc. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
LPV 4
LON module with 4 temperature and 4 voltage inputs. Suitable to collect temperatures with Pt 1000 sensors and voltages of e.g. electrical vent and mixing valves, valve positions etc.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
LPV 4 IP65 housing
LON module with 4 temperature and 4 voltage inputs. Suitable to collect temperatures with Pt 1000 sensors and voltages of e.g. electrical vent and mixing valves, valve positions etc.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
LNV 4
LON module with 4 temperature and 4 voltage inputs. Suitable to collect temperature and voltage data, e.g. electrical vent and mixing valves, valve positions etc. Furthermore it is possible to change from standard Ni1000 to Ni1000 TK 5000 temperature sensor. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
LNV 4 IP65 housing
LON module with 4 temperature and 4 voltage inputs. Suitable to collect temperature and voltage data, e.g. electrical vent and mixing valves, valve positions etc. Furthermore it is possible to change from standard Ni1000 to Ni1000 TK 5000 temperature sensor. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
LNTC
LON module with 4 temperature and 4 voltage inputs. Suitable to collect temperature data with NTC 20K sensors and voltage values, e.g. of electrical vent and mixing valves, valve positionis etc. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
LIE 4
LON module with 4 current and 4 voltage inputs. Suitable to collect current and voltage values, e.g. in the field of industry and refrigeration engineering.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
LAF 4 IP65 housing
LON module with 4 temperature and 4 voltage inputs to record voltages of e.g. active temperature sensors, electrical ventilation and mixing valves, valve positions etc.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
^ top page |
|
Analog output modules |
|
LAAp
LON module with 4 analogue outputs. Suitable as encoder for regulating variables for e.g. electrical vent and mixing valves, valve positions etc. The different outputs are activated proportionally by the network variables SNVT and accordingly they provide a voltage between 0 and 10 Volt. In addition the outputs can be set to previously defined voltage values. The manual position of the potentiometer is signalled. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
LAA 4 IP65 housing
LON module with 4 analogue outputs. Suitable as encoder for regulating variables for i. e. electrical vent and mixing valves, valve positions etc. The different outputs are activated proportionally by the network variables SNVT and accordingly they provide a voltage between 0 and 10 Volt. In addition the outputs can be set to previously defined voltage values. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
^ top page |
|
Combined I/O modules |
|
NC1101
LON I/O module with 1 isolated analog input, 6 isolated polarity insensitive digital inputs and 6 relay outputs. Built-in real-time clock; LED indicator for each input and output. Wide power supply range from 9 to 70VDC (18 to 48VAC).
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
NC1106
LON I/O module with 6 isolated polarity insensitive digital inputs and 6 relay outputs. Built-in real-time clock; LED indicator for each input and output. Wide power supply range from 9 to 70VDC (18 to 48VAC). |
|
|
|
|
|
|
|
|
|
LCU100-4PL
LON module with 4 digital inputs and 4 relay outputs. Communication – PL, ANSI/EIA 709.2-A-2000. Direct control of 4 loads. Possibility to switch 3-phase loads. Switches up to 100A/channel. Feedback for the channel status. |
|
|
|
|
|
|
|
|
LAM
LON I/O module with 2 analogue inputs, 2 analogue and 2 digital outputs. Suitable to control for example vent valves and to issue an alarm signal at a preset threshold. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
LIO 4/2
LON I/O module with 4 digital inputs and 2 relay outputs. Suitable for example to take up light switches and window contacts in a room and to switch two batten luminaires or control window blinds. Or, besides other applications it can control two motor driven fire protection valves. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
LIO 4/2 IP65 housing
LON I/O module with 4 digital inputs and 2 relay outputs. Suitable for example to take up light switches and window contacts in a room and to switch two batten luminaires or control window blinds. Or, besides other applications it can control two motor driven fire protection valves. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
LDM 4/4
LON I/O module with 4 digital inputs, 2 relay outputs and 2 digital outputs. Suitable to interrogate for example switching status and to switch motors or other actors as a result. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
LDP
LON three point module with 6 digital inputs, 2 two-stage relay outputs and 2 digital outputs. It is suited to operate multi-stage pumps, fans, burners or similar devices. |
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
^ top page |
|
LON door installation modules |
|
LM1 annunciator module
Tact switch and display module for 19” frames. Suitable as manual control facility in cabinet doors or remote control panels. If operated with factory settings it serves as annunciator module for collected failure signals in the LON door installation system.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
LM2 indicator module
Indicator module with 10 LEDs for 19" frames. Suitable as annunciator module in cabinet doors or remote control panels.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
|
|
|
|
LS1 switch module
Switch and indicator module for 19" frames. Suitable as manual control facility in cabinet doors or remote control panels.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
|
|
|
|
LT1 tact switch module
Tact switch and indicator module for 19" frames. Suitable as manual control facility in cabinet doors or remote control panels.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
|
|
|
|
LT2 door installation module
Tact switch and indicator module for 19" frames. Suited as manual operation level in electrical cabinet doors or remote control panels to operate motor powered fire shutters. The LT2 allows to conduct test runs or to commute to the inversed state of the shutter – 4 buttons, 4 LED.
The module indicates the status fire alarm, shutter position and pollution. The module is designed for 5 units and is provided with an integrated communication control.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
|
|
LT3 door installation module
Tact switch and indicator for 19" frames. Suited as manual operation level in electrical cabinet doors or remote control panels – 2 buttons, 8 LED.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
|
|
|
|
LA1 analogue data encoder
Indicator and set point encoder module for 19" frames. Suitable as indicator and manual control of analogue signals in cabinet doors or remote control panels.
|
|
More information: Datasheet PDF |
|
|
|
|
|
|
|
|
|
|
^ top page |
|
Accessories |
|
|
|
|
|
DPA8 Channel amplifier
The module is designed to amplify the capacity of digital outputs of different controllers in order to control heavy loads. The module can controls active and inductive loads. Input voltage range from 15 to 36VDC. Output voltage 24VDC/2A. Maximum switch voltage of each input is 36VDC. Output power supply 24VDC (range from 18 to 36VDC). |
|
|
|
|
|
|
|
|
|
|
|
|
|
^ top page |